Specification
|
Item Name
|
Thermocouple
|
Item No.
|
PM-TM
|
Size
|
Customized
|
Calibrations of thermocouple
|
R/S/B/K/N/J/E/T etc
|
Response time
|
3-5 s
|
Temperature
|
0 to 1200 deg C
|
Probe material
|
Miner coated and stainless steel sheaths
|
Types
|
Probe, Screw, 1/4 NPT, M6, M8
|
Shapes
|
Straight, 45° bend or 90° bend
|
Accuracy
|
Class A or Class B
|
Certificates
|
CE, RoHs
|
Packaging
|
Fumigation free wooden case
|
Material
|
Probe
|
SS 304, SS 316L
|
Wire
|
Fiber glass wire, SS braided wire, teflon wire, PETF wire, silicone wire etc
|
Accessories Information
|
Thread or flange
|
Customized
|
Connection box
|
Optainal
|
Connectors
|
Optainal
|
Introductions of Thermocouple
|
A thermocouple is a simple, robust and cost-effective temperature sensor used in a wide range of temperature measurement processes. It consists of two dissimilar metal wires, joined at one end. When properly configured, thermocouples can provide measurements over a wide range of temperatures.
Known for their versatility as temperature sensors, thermocouples are manufactured in a variety of styles, such as thermocouple probes, thermocouple probes with connectors, transition joint thermocouple probes, infrared thermocouples, bare wire thermocouple or even just thermocouple wire.
|
The feature of Thermocouple
|
Customized diameter, sheath lengths and lead length
|
Stainless steel braided or hose protection
|
K, J, T and E calibrations
|
Grounded, ungrounded and exposed junctions
|
Flat and drill point
|
Epoxy sealed cold ends
|
Flexible extensions
|
Miner coated and stainless steel sheaths
|
Straight, 45° bend or 90° bend
|
12 mm and 15 mm locking bayonet caps
|
The applications of thermocouples
|
1. Food processing equipment
|
2. De-icing
|
3. Plating baths
|
4. Industrial processing
|
6. Medical equipment
|
7. Pipe tracing control
|
8. Industrial heat treating
|
9. Packaging equipment
|
10. Liquid temperature measurement
|
11. Refrigerator temperature control
|
12. Oven temperature control
|
Datasheet
|
Type
|
Temperature range (°C)
|
Tolerance class (°C)
|
Continuous
|
Short-term
|
One
|
Two
|
Low
|
High
|
Low
|
High
|
K
|
0
|
1100
|
−180
|
1300
|
−40 – 375: ±1.5
|
−40 – 333: ±2.5
|
375 – 1000: ±0.004×T
|
333 – 1200: ±0.0075×T
|
J
|
0
|
750
|
−180
|
800
|
−40 – 375: ±1.5
|
−40 – 333: ±2.5
|
375 – 750: ±0.004×T
|
333 – 750: ±0.0075×T
|
N
|
0
|
1100
|
−270
|
1300
|
−40 – 375: ±1.5
|
−40 – 333: ±2.5
|
375 – 1000: ±0.004×T
|
333 – 1200: ±0.0075×T
|
R
|
0
|
1600
|
−50
|
1700
|
0 – 1100: ±1.0
|
0 – 600: ±1.5
|
1100 – 1600: ±0.003×(T − 767)
|
600 – 1600: ±0.0025×T
|
S
|
0
|
1600
|
−50
|
1750
|
0 – 1100: ±1.0
|
0 – 600: ±1.5
|
1100 – 1600: ±0.003×(T − 767)
|
600 – 1600: ±0.0025×T
|
B
|
200
|
1700
|
0
|
1820
|
Not available
|
600 – 1700: ±0.0025×T
|
T
|
−185
|
300
|
−250
|
400
|
−40 – 125: ±0.5
|
−40 – 133: ±1.0
|
125 – 350: ±0.004×T
|
133 – 350: ±0.0075×T
|
E
|
0
|
800
|
−40
|
900
|
−40 – 375: ±1.5
|
−40 – 333: ±2.5
|
375 – 800: ±0.004×T
|
333 – 900: ±0.0075×T
|
Chromel/AuFe
|
−272
|
300
|
N/A
|
N/A
|
Reproducibility 0.2% of the voltage.
|
Each sensor needs individual calibration.
|
|
RFQ
|
Type of thermocouple, such as K type, J type or E type etc
|
Size of thermocouple
|
Type of the extended wire and length
|
Thread type if have
|
Quantity
|