Saving energy, start here

Thermocouple

Short Description:

A thermocouple is a simple, robust and cost-effective temperature sensor used in a wide range of temperature measurement processes. It consists of two dissimilar metal wires, joined at one end. When properly configured, thermocouples can provide measurements over a wide range of temperatures.


  • FOB Price: US $2- 30 / Piece
  • Min.Order Quantity: 10 Piece/Pieces
  • Supply Ability: 100000 Pieces per Month
  • Shipping: Express, ocean shipping, air shipping
  • Payment Terms: T/T, PAYPAL, WESTERN UNION
  • Product Detail

    Product Tags

    Specification

    Item Name

    Thermocouple

    Item No.

    PM-TM

    Size

    Customized

    Calibrations of thermocouple

    R/S/B/K/N/J/E/T etc

    Response time

    3-5 s

    Temperature

    0 to 1200 deg C

    Probe material

    Miner coated and stainless steel sheaths

    Types

    Probe, Screw, 1/4 NPT, M6, M8

    Shapes

    Straight, 45° bend or 90° bend

    Accuracy

    Class A or Class B

    Certificates

    CE, RoHs

    Packaging

    Fumigation free wooden case

    Material

    Probe

    SS 304, SS 316L

    Wire

    Fiber glass wire, SS braided wire, teflon wire, PETF wire, silicone wire etc

    Accessories Information

    Thread or flange

    Customized

    Connection box

    Optainal

    Connectors

    Optainal

    Introductions of Thermocouple

    A thermocouple is a simple, robust and cost-effective temperature sensor used in a wide range of temperature measurement processes. It consists of two dissimilar metal wires, joined at one end. When properly configured, thermocouples can provide measurements over a wide range of temperatures.
     
    Known for their versatility as temperature sensors, thermocouples are manufactured in a variety of styles, such as thermocouple probes, thermocouple probes with connectors, transition joint thermocouple probes, infrared thermocouples, bare wire thermocouple or even just thermocouple wire.

    The feature of Thermocouple

    Customized diameter, sheath lengths and lead length

     Stainless steel braided or hose protection

     K, J, T and E calibrations

     Grounded, ungrounded and exposed junctions

     Flat and drill point

     Epoxy sealed cold ends

     Flexible extensions

     Miner coated and stainless steel sheaths

     Straight, 45° bend or 90° bend

     12 mm and 15 mm locking bayonet caps

    The applications of thermocouples

    1. Food processing equipment

    2. De-icing

    3. Plating baths

    4. Industrial processing

    6. Medical equipment

    7. Pipe tracing control

    8. Industrial heat treating

    9. Packaging equipment

    10. Liquid temperature measurement

    11. Refrigerator temperature control

    12. Oven temperature control

    Datasheet

    Type

    Temperature range (°C)

    Tolerance class (°C)

    Continuous

    Short-term

    One

    Two

    Low

    High

    Low

    High

    K

    0

    1100

    −180

    1300

    −40 – 375: ±1.5

    −40 – 333: ±2.5

    375 – 1000: ±0.004×T

    333 – 1200: ±0.0075×T

    J

    0

    750

    −180

    800

    −40 – 375: ±1.5

    −40 – 333: ±2.5

    375 – 750: ±0.004×T

    333 – 750: ±0.0075×T

    N

    0

    1100

    −270

    1300

    −40 – 375: ±1.5

    −40 – 333: ±2.5

    375 – 1000: ±0.004×T

    333 – 1200: ±0.0075×T

    R

    0

    1600

    −50

    1700

    0 – 1100: ±1.0

    0 – 600: ±1.5

    1100 – 1600: ±0.003×(T − 767)

    600 – 1600: ±0.0025×T

    S

    0

    1600

    −50

    1750

    0 – 1100: ±1.0

    0 – 600: ±1.5

    1100 – 1600: ±0.003×(T − 767)

    600 – 1600: ±0.0025×T

    B

    200

    1700

    0

    1820

    Not available

    600 – 1700: ±0.0025×T

    T

    −185

    300

    −250

    400

    −40 – 125: ±0.5

    −40 – 133: ±1.0

    125 – 350: ±0.004×T

    133 – 350: ±0.0075×T

    E

    0

    800

    −40

    900

    −40 – 375: ±1.5

    −40 – 333: ±2.5

    375 – 800: ±0.004×T

    333 – 900: ±0.0075×T

    Chromel/AuFe

    −272

    300

    N/A

    N/A

    Reproducibility 0.2% of the voltage.

    Each sensor needs individual calibration.

    RFQ

    Type of thermocouple, such as K type, J type or E type etc

    Size of thermocouple

    Type of the extended wire and length

    Thread type if have

    Quantity


  • Previous:
  • Next:

  • 
    WhatsApp Online Chat !